Set DCP 3000 + VSP 3000
BrandTech Scientific

Set DCP 3000 + VSP 3000

SKU: 20683190
Contact for pricing
Set DCP 3000 + VSP 3000 from BRAND (BrandTech Scientific). vacuum measuring device for connecting external vacuum sensors for measurements directly on the sy…

The fully electronic vacuum measuring device DCP 3000 is both versatile and decisive with its mechanical robustness, measuring accuracy and reliability. The large, illuminated display provides the measured value display of all connected sensors via an easy-to-use rotary control. Up to eight vacuum sensors (four of each type VSK 3000 / VACUU·VIEW and VSP 3000 / VACUU·VIEW extended) can be connected to the DCP 3000. The measurement can be carried out directly on the application. The DCP 3000 enables a relative pressure measurement (reference sensor VSK 3000) as well as working with pressure-dependent switching points by specifying switch-on and switch-off points on an external valve. The vacuum measuring device can also be used as a data logger with up to 32,000 measuring points. The data is read out via the serial interface (RS 232C). The vacuum sensor VSP 3000 is based on the gas thermal conductivity (Pirani) principle for the wide measuring range from atmospheric pressure to 10<sup>-3</sup> mbar. Thanks to its structure made of chemically resistant plastics (PBT, PUR) and ceramics, it offers significantly higher chemical resistance and robustness compared to conventional Pirani sensors with fine wire metal filaments. Please also note our alternative product VACUU·VIEW extended.

Key Features

Specifications

Weight 0.44 kg
Manufacturer BRAND (BrandTech Scientific)
Items supplied Vacuum gauge with external vacuum sensor VSP 3000, ready for operation, with wall-plug power supply and manual.
Protection class IEC 60529 IP 20
Upper ambient temperature (operation) 40 °C
Lower ambient temperature (operation) 10 °C
Dimension B in mm 124 mm
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Dimension L in mm 144 mm
Dimension H in mm 114 mm
NRTL certification Yes
Interface RS 232C
Upper measuring limit in mbar/hPa 1000 mbar
Upper measuring limit in torr 750 torr
Lower measuring limit in mbar/hPa 1 x 10 -3
Lower measuring limit in torr 1 x 10 -3 torr
Measurement principle Thermal conductivity (Pirani), chemically resistant plastics / ceramics
Accuracy of measurement +- 15% of indicated value in the range 0.01-5 mbar/hPa/torr mbar/hPa/torr
Vacuum sensor VSP 3000
Vacum connection Small flange KF DN 16 and hose nozzle DN 6/10 mm
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Material of outer housing Robust plastic housing with good chemical resistance
Protection class UL50E Type 1
Protection class front side IEC 60529 IP 42
Cable length connection in m 2 m
Cable length of vacuum sensor 2 m