The fully electronic vacuum measuring device DCP 3000 is both versatile and decisive with its mechanical robustness, measuring accuracy and reliability. The large, illuminated display provides the measured value display of all connected sensors via an easy-to-use rotary control. Up to eight vacuum sensors (four of each type VSK 3000 / VACUU·VIEW and VSP 3000 / VACUU·VIEW extended) can be connected to the DCP 3000. The measurement can be carried out directly on the application. The DCP 3000 enables a relative pressure measurement (reference sensor VSK 3000) as well as working with pressure-dependent switching points by specifying switch-on and switch-off points on an external valve. The vacuum measuring device can also be used as a data logger with up to 32,000 measuring points. The data is read out via the serial interface (RS 232C). The ceramic membrane vacuum sensor VSK 3000 is suitable for the measuring range from atmospheric pressure to 0.1 mbar. It measures regardless of the gas type and is highly chemically resistant, which means that the measurement can be carried out directly at the process, with excellent measurement accuracy and high long-term and temperature stability. Please also note our alternative product VACUU·VIEW.
| Weight | 0.44 kg |
| Manufacturer | BRAND (BrandTech Scientific) |
| Items supplied | Vacuum gauge with external vacuum sensor VSK 3000, ready for operation, with kit hose nozzle DN 6/10 mm, wall-plug power supply and manual. |
| Protection class IEC 60529 | IP 20 |
| Upper ambient temperature (operation) | 40 °C |
| Lower ambient temperature (operation) | 10 °C |
| Dimension B in mm | 124 mm |
| Lower ambient temperature (storage) | -10 °C |
| Upper ambient temperature (storage) | 60 °C |
| Dimension L in mm | 144 mm |
| Dimension H in mm | 114 mm |
| ATEX conformity | II 3/- G Ex h IIC T3 Gc X Internal Atm. only |
| NRTL certification | Yes |
| Interface | RS 232C |
| Upper measuring limit in mbar/hPa | 1080 mbar |
| Upper measuring limit in torr | 810 torr |
| Lower measuring limit in mbar/hPa | 0.1 |
| Lower measuring limit in torr | 0.1 torr |
| Measurement principle | Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure |
| Accuracy of measurement | < +- 1 mbar/hPa/torr / +- 1 digit (after adjustment, constant temp.) mbar/hPa/torr |
| Vacuum sensor | VSK 3000 |
| Temperature coefficient | < 0.07 mbar/hPa/0.05 torr /K mbar/hPa/torr /K |
| Vacum connection | Small flange KF DN 16, PTFE tubing connection 10/8 mm, hose nozzle DN 6/10 mm |
| Max. media temperature for continuous operation | 40 °C |
| Max. media temperature short term | 80 °C |
| Material of outer housing | Robust plastic housing with good chemical resistance |
| Protection class UL50E | Type 1 |
| Protection class front side IEC 60529 | IP 42 |
| Cable length connection in m | 2 m |
| Cable length of vacuum sensor | 2 m |