HomeTemperature CalibrationPharmaceutical & GMP

Temperature Calibration for Pharmaceutical & GMP Laboratories

Femto Scientific delivers ISO/IEC 17025 accredited temperature calibration built for FDA 21 CFR Part 211 and USP Chapter <1079> — multi-point RTD and thermocouple bath calibration with documented measurement uncertainty, as-found/as-left data, and unbroken NIST traceability to ITS-90, so the sensors, probes, and data loggers behind your stability chambers, incubators, autoclaves, and cold storage pass inspection and your temperature data holds up under audit.

  • FDA 21 CFR Part 211 & Part 58 aligned records
  • Documented measurement uncertainty (k=2)
  • As-found & as-left data for change control
  • Multi-point RTD & thermocouple bath calibration
  • USP <1079> & <1118> monitoring compliance
  • NIST-traceable references to ITS-90
  • Onsite service with zero shipping downtime
  • Electronic certificates for QMS / LIMS

Accredited temperature calibration your quality unit can defend against a data-integrity finding.

Why GMP Laboratories Require ISO 17025 Accredited Temperature Calibration

In a cGMP environment, every RTD, thermocouple, and data logger is a measuring device whose accuracy flows directly into stability data, batch records, and release decisions. FDA 21 CFR Part 211 and USP Chapter <1079> set the calibration expectations; ISO/IEC 17025 accreditation provides the documented uncertainty and ITS-90 traceability that prove the calibration can actually demonstrate compliance.

FDA 21 CFR Part 211 & Part 58

Instruments must be calibrated on a written schedule with limits, results, and remedial action recorded. Our certificates capture the calibration date, results, NIST traceability, and as-found/as-left data your quality unit needs for Part 211 cGMP and Part 58 GLP calibration programs.

ITS-90 & Multi-Point Bath Calibration

We calibrate RTDs per ASTM E1137 and thermocouples per ASTM E220/E230 by comparison against NIST-traceable reference PRTs in calibrated temperature baths and dry-blocks — multiple points across your actual set-point range, each documented to ITS-90 with reported uncertainty.

Data Integrity & Uncertainty

Without a reported measurement uncertainty, a certificate cannot demonstrate fitness for purpose. Accredited calibration with expanded uncertainty (k=2, 95%) gives you the attributable, accurate temperature evidence auditors expect under ALCOA+ and 21 CFR Part 11.

ISO 17025 accredited RTD and thermocouple calibration for a cGMP pharmaceutical laboratory

A Complete, Documented ITS-90 Traceable Calibration

Every accredited temperature calibration characterizes sensor performance across your actual use range — not just a single point — and records as-found data so an out-of-tolerance finding can be impact-assessed under change control.

  • Multi-point calibration at your chamber set points
  • RTDs, thermocouples, PRTs, digital probes & transmitters
  • Temperature data loggers for stability monitoring
  • As-found & as-left data with adjustment
  • Expanded measurement uncertainty (k=2)
  • NIST-traceable references to ITS-90

Compare service levels and documentation on the temperature calibration service page, or see our temperature & humidity mapping for the chamber and storage studies your calibrated probes support.

Pharmaceutical &amp; GMP Temperature Calibration FAQs

Put Your Temperature Sensors on a Defensible GMP Calibration Program

Tell us your instrument count, types, and required service level — we’ll return a quote with turnaround options and a recommended calibration interval for your compliance program.

Request a GMP Quote +1-800-631-0263